The Sealminer A2 Air is designed specifically for air-cooled environments. This article outlines the risks, manufacturer recommendations, and warranty implications of using the A2 Air in immersion environments, as well as common inquiries from users attempting such modifications.
Can I Use the Sealminer A2 Air in an Immersion Tank?
The Sealminer A2 Air Cooling model is not designed for immersion cooling. This is strongly advised against for several reasons:
- Dielectric fluids used in immersion setups can wash away or degrade protective coating on internal components, increasing the risk of corrosion and component failure.
- Fan monitoring system: The machine includes a fan monitoring feature that prevents boot-up if fans are removed or not functioning properly.
What Happens if I Remove the Fans for Immersion Use?
Removing the fans or operating the unit without its intended air-cooling system may result in:
- Failure to boot: The miner will repeatedly attempt to start but may not complete the boot process due to missing fan input.
- Fan abnormal” alerts: The system detects the missing fans and prevents normal operation.
- Warranty void: Immersion use or modification of the cooling system may void your Sealminer A2 Air warranty.